• 28.5 V DC Analog Panel Load Banks AP

    Dekal Load Banks

    The shortest lead times in industry

28.5 V DC ANALOG PANEL LOAD BANKS

Color variations

Advantages

  • Simple operation suitable for non-trained operators
  • Silent operations < 70 dB(A) at the distance of 7m / 23Ft
  • Suitable for workshop and/or airside operation
  • Environmental operating temperature from -20 ºC to 55 ºC / -4 ºF to 122 ºF
  • Transport casing with pull up handle as standard for each load bank
  • Triple thermal protection – extremely resistant to high temperature
  • Cant protection – load bank works only in horizontal position
  • Phase detection – load bank works only if all ABC phases are available
  • Phase rotation indicator – phase sequence of three-phase voltages
  • Fine regulation as standard for all Digital and Analogue 400 Hz AC load banks
  • Aluminum housing and non-corrosive parts
  • High component quality control by manufacturer
  • High reliability – effective standardization process
  • Isolated jack sockets – unique user friendly safety feature for external voltage test
  • Spare parts availability and accurate on-time deliveries
  • Short worldwide delivery period with tracking feature & insurance
  • 2 years full warranty with extension option for all DEKAL load banks
  • CE certification – health, safety, and environmental protection standards
  • Made for GPU’s testing procedure according to ISO 6858, DFS 400, ARP 5015
  • Classification CE marking, DIN, VDE, IEC, IP 21 protection rate level

28.5 V DC ANALOG PANEL LB

Select an available model:

TECHNICAL SPECIFICATION
DLB-03AP
VOLTAGE [V]
28.5 V DC ± 10 %
LOAD REGIME OPTIONS [A]
300 A ± 20 %
LOAD TEST PROCEDURE TYPE
/
LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS & DECREASING]
/
LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS – SELECTED MANUALLY]
300 A CONTINUOUS LOAD
[DECREASING ESS – SELECTED MANUALLY]
/
FORCED AIR COOLING [m3/min & CFM]
22.05 m3/min – 780 CFM
MEASUREMENTS & INDICATIONS
ANALOGUE VOLT METER
ANALOGUE AMP METER
VOLT METER – MOVING IRON CLASS 1.5,
AMP METER – MOVING IRON CLASS 1.5
LIGHT INDICATION
28 V DC POWER INDICATION, FAILURE INDICATOR
GPU TESTING PROCEDURE
AND ENGINE DECARBONISING*
*LOAD 300A for 20 minutes
OPERATING TEMPERATURE [°C / °F]
from -20 °C to 55 °C / from -4 °F to 122 °F
NOISE LEVEL [dB] AT DISTANCE [m/Ft]
< 70 dB(A) at the distance of 7m / 23Ft
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
570 x 230 x 450 / 18
22.5 x 9 x 18 / 39
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
620 x 280 x 690 / 17
24.4 x 11 x 27.2 / 37
LOAD BANK PAINTING / TRANSPORT CASING
POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM
Including transport carrying case per unit / All specifications are subject to change without further notice
TECHNICAL SPECIFICATION
DLBM-ESS-15AP
VOLTAGE [V]
28.5 V DC ± 10 %
LOAD REGIME OPTIONS [A]
300 A OR 600 A CONTINUOUS &
1500 A ± 20 % ESS PROCEDURE
LOAD TEST PROCEDURE TYPE
AIRCRAFT ENGINE START SIMULATION (ESS) in duration of 35 seconds DECREASING
LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS & DECREASING]
SEQUENCE OF 6 STEPS
ENGINE START SIMULATION
Step 1: 1500 A for 1 second
Step 2: 1200 A for 3 seconds
Step 3: 1000 A for 10 seconds
Step 4: 800 A for 20 seconds
Step 5: 700 A for 30 seconds
Step 6: 400 A for 35 seconds
LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS – SELECTED MANUALLY]
300 A CONTINUOUS LOAD
600 A CONTINUOUS LOAD
[DECREASING ESS – SELECTED MANUALLY]
1500 A DECREASING ESS
FORCED AIR COOLING [m3/min & CFM]
44.10 m3/min – 1560 CFM
MEASUREMENTS & INDICATIONS
ANALOGUE VOLT METER
ANALOGUE AMP METER
VOLT METER – MOVING IRON CLASS 1.5,
AMP METER – MOVING IRON CLASS 1.5
LIGHT INDICATION
28 V DC POWER INDICATION, FAILURE INDICATOR
GPU TESTING PROCEDURE
AND ENGINE DECARBONISING*
*LOAD 300 A or 600 A 30 / 15 minutes
ESS in 6 STEPS 100% -> 0% 35 seconds
OPERATING TEMPERATURE [°C / °F]
from -20 °C to 55 °C / from -4 °F to 122 °F
NOISE LEVEL [dB] AT DISTANCE [m/Ft]
< 70 dB(A) at the distance of 7m / 23Ft
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
570 x 230 x 450 / 20
22.5 x 9 x 18 / 44
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
620 x 280 x 690 / 17
24.4 x 11 x 27.2 / 37
LOAD BANK PAINTING / TRANSPORT CASING
POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM
Including transport carrying case per unit / All specifications are subject to change without further notice
TECHNICAL SPECIFICATION
DLBM-ESS-20AP
VOLTAGE [V]
28.5 V DC ± 10 %
LOAD REGIME OPTIONS [A]
300 A OR 600 A CONTINUOUS &
2000 A ± 20 % ESS PROCEDURE
LOAD TEST PROCEDURE TYPE
AIRCRAFT ENGINE START SIMULATION (ESS) in duration of 35 seconds DECREASING
LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS & DECREASING]
SEQUENCE OF 6 STEPS
ENGINE START SIMULATION
Step 1: 2000 A for 1 second
Step 2: 1700 A for 3 seconds
Step 3: 1200 A for 10 seconds
Step 4: 1000 A for 20 seconds
Step 5: 700 A for 30 seconds
Step 6: 400 A for 35 seconds
LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS – SELECTED MANUALLY]
300 A CONTINUOUS LOAD
600 A CONTINUOUS LOAD
[DECREASING ESS – SELECTED MANUALLY]
2000 A DECREASING ESS
FORCED AIR COOLING [m3/min & CFM]
44.10 m3/min – 1560 CFM
MEASUREMENTS & INDICATIONS
ANALOGUE VOLT METER
ANALOGUE AMP METER
VOLT METER – MOVING IRON CLASS 1.5,
AMP METER – MOVING IRON CLASS 1.5
LIGHT INDICATION
28 V DC POWER INDICATION, FAILURE INDICATOR
GPU TESTING PROCEDURE
AND ENGINE DECARBONISING*
*LOAD 300 A or 600 A 30 / 15 minutes
ESS in 6 STEPS 100% -> 0% 35 seconds
OPERATING TEMPERATURE [°C / °F]
from -20 °C to 55 °C / from -4 °F to 122 °F
NOISE LEVEL [dB] AT DISTANCE [m/Ft]
< 70 dB(A) at the distance of 7m / 23Ft
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
570 x 230 x 450 / 25
22.5 x 9 x 18 / 55
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
620 x 280 x 690 / 17
24.4 x 11 x 27.2 / 37
LOAD BANK PAINTING / TRANSPORT CASING
POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM
Including transport carrying case per unit / All specifications are subject to change without further notice
TECHNICAL SPECIFICATION
DLBM-ESS-25AP
VOLTAGE [V]
28.5 V DC ± 10 %
LOAD REGIME OPTIONS [A]
300 A CONTINUOUS OR 1400 A,
2500 A ± 20 % ESS PROCEDURE
LOAD TEST PROCEDURE TYPE
AIRCRAFT ENGINE START SIMULATION (ESS) in duration of 35 seconds DECREASING
LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS & DECREASING]
SEQUENCE OF 6 STEPS
ENGINE START SIMULATION
Step 1: 2500 A for 1 second
Step 2: 1900 A for 3 seconds
Step 3: 1300 A for 10 seconds
Step 4: 1000 A for 20 seconds
Step 5: 700 A for 30 seconds
Step 6: 400 A for 35 seconds
LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS – SELECTED MANUALLY]
300 A CONTINUOUS LOAD
600 A CONTINUOUS LOAD
[DECREASING ESS – SELECTED MANUALLY]
1400 A or 2500 A DECREASING ESS
FORCED AIR COOLING [m3/min & CFM]
44.10 m3/min – 1560 CFM
MEASUREMENTS & INDICATIONS
ANALOGUE VOLT METER
ANALOGUE AMP METER
VOLT METER – MOVING IRON CLASS 1.5,
AMP METER – MOVING IRON CLASS 1.5
LIGHT INDICATION
28 V DC POWER INDICATION, FAILURE INDICATOR
GPU TESTING PROCEDURE
AND ENGINE DECARBONISING*
*LOAD 300 A or 600 A 30 / 15 minutes
ESS in 6 STEPS 100% -> 0% 35 seconds
OPERATING TEMPERATURE [°C / °F]
from -20 °C to 55 °C / from -4 °F to 122 °F
NOISE LEVEL [dB] AT DISTANCE [m/Ft]
< 70 dB(A) at the distance of 7m / 23Ft
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
570 x 230 x 450 / 26
22.5 x 9 x 18 / 57
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
620 x 280 x 690 / 17
24.4 x 11 x 27.2 / 37
LOAD BANK PAINTING / TRANSPORT CASING
POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM
Including transport carrying case per unit / All specifications are subject to change without further notice

Color variations

error: Content is protected !!
Scroll to Top