400 HZ DIGITAL WIFI & USB LOAD BANKS
Advantages
- Simple operation suitable for non-trained operators
- Silent operations < 70 dB(A) at the distance of 7m / 23Ft
- Suitable for workshop and/or airside operation
- Environmental operating temperature from -20 ºC to 55 ºC / -4 ºF to 122 ºF
- Transport casing with pull up handle as standard for each load bank
- Triple thermal protection – extremely resistant to high temperature
- Cant protection – load bank works only in horizontal position
- Phase detection – load bank works only if all ABC phases are available
- Phase rotation indicator – phase sequence of three-phase voltages
- Fine regulation as standard for all Digital and Analogue 400 Hz AC load banks
- Aluminum housing and non-corrosive parts
- High component quality control by manufacturer
- High reliability – effective standardization process
- Isolated jack sockets – unique user friendly safety feature for external voltage test
- Spare parts availability and accurate on-time deliveries
- Short worldwide delivery period with tracking feature & insurance
- 2 years full warranty with extension option for all DEKAL load banks
- CE certification – health, safety, and environmental protection standards
- Made for GPU’s testing procedure according to ISO 6858, DFS 400, ARP 5015
- Classification CE marking, DIN, VDE, IEC, IP 21 protection rate level
Select an available model:
TECHNICAL SPECIFICATION | ALBM-45DW |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 48 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 5 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW |
FORCED AIR COOLING [m³/min & CFM] | 44.10 m³/min – 1560 CFM |
MEASUREMENTS & INDICATIONS | |
---|---|
DIGITAL POWER METER PARAMETERS WiFi & USB INTERFACE SPECIFICATIONS | 3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003; DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA; WiFi NETWORK OR USB PLUG IN CONNECTION FOR DATA PRINTOUT/ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 5 minutes; LOAD decrease from 100 -> 0% 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 45 minutes; LOAD decrease from 100 -> 0% 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 25 23.6 x 9.05 x 24.8 / 55 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|
TECHNICAL SPECIFICATION | ALBM-80DW |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 80 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 9 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW 48 – 56 kW 56 – 64 kW 64 – 72 kW 72 – 80 kW |
FORCED AIR COOLING [m³/min & CFM] | 66.15 m³/min – 2340 CFM |
MEASUREMENTS & INDICATIONS | |
---|---|
DIGITAL POWER METER PARAMETERS WiFi & USB INTERFACE SPECIFICATIONS | 3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003; DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA; WiFi NETWORK OR USB PLUG IN CONNECTION FOR DATA PRINTOUT/ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 5 minutes; LOAD decrease from 100 -> 0% 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 45 minutes; LOAD decrease from 100 -> 0% 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 27 23.6 x 9.05 x 24.8 / 59 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|
TECHNICAL SPECIFICATION | ALBM-100DW |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 100 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 12 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW 48 – 56 kW 56 – 64 kW 64 – 72 kW 72 – 80 kW 80 – 88 kW 88 – 96 kW 96 – 104 kW |
FORCED AIR COOLING [m³/min & CFM] | 88.20 m³/min – 3120 CFM |
MEASUREMENTS & INDICATIONS | |
---|---|
DIGITAL POWER METER PARAMETERS WiFi & USB INTERFACE SPECIFICATIONS | 3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003; DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA; WiFi NETWORK OR USB PLUG IN CONNECTION FOR DATA PRINTOUT/ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 5 minutes; LOAD decrease from 100 -> 0% 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 45 minutes; LOAD decrease from 100 -> 0% 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 30 23.6 x 9.05 x 24.8 / 66 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|
TECHNICAL SPECIFICATION | ALBM-120DW |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 120 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 14 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW 48 – 56 kW 56 – 64 kW 64 – 72 kW 72 – 80 kW 80 – 88 kW 88 – 96 kW 96 – 104 kW 104 – 112 kW 112 – 120 kW |
FORCED AIR COOLING [m³/min & CFM] | 88.20 m³/min – 3120 CFM |
MEASUREMENTS & INDICATIONS | |
---|---|
DIGITAL POWER METER PARAMETERS WiFi & USB INTERFACE SPECIFICATIONS | 3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003; DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA; WiFi NETWORK OR USB PLUG IN CONNECTION FOR DATA PRINTOUT/ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 5 minutes; LOAD decrease from 100 -> 0% 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 45 minutes; LOAD decrease from 100 -> 0% 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 33 23.6 x 9.05 x 24.8 / 73 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|
TECHNICAL SPECIFICATION | ALBM-140DW |
---|---|
VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
LOAD / POWER [kW / kVA cosφ=1] | 0 – 140 kW ± 5 % |
FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] | 14 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW 48 – 56 kW 56 – 64 kW 64 – 72 kW 72 – 80 kW 80 – 88 kW 88 – 96 kW 96 – 104 kW 104 – 112 kW 112 – 120 kW 120 – 128 kW 128 – 136 kW 136 – 144 kW |
FORCED AIR COOLING [m³/min & CFM] | 88.20 m³/min – 3120 CFM |
MEASUREMENTS & INDICATIONS | |
---|---|
DIGITAL POWER METER PARAMETERS WiFi & USB INTERFACE SPECIFICATIONS | 3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003; DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA; WiFi NETWORK OR USB PLUG IN CONNECTION FOR DATA PRINTOUT/ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE |
LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
GPU TESTING PROCEDURE* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 5 minutes; LOAD decrease from 100 -> 0% 10 minutes |
ENGINE DECARBONISING* | *Proposal procedure: LOAD raising from 0 -> 100% 30 seconds; HOLD at 100% 45 minutes; LOAD decrease from 100 -> 0% 15 minutes |
DIMENSIONS & WEIGHT | |
---|---|
LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs | 600 x 230 x 630 / 35 23.6 x 9.05 x 24.8 / 77 |
TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs | 710 x 290 x 860 / 19 27.9 x 11.4 x 33.9 / 42 |
LOAD BANK PAINTING / TRANSPORT CASING | POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM |
Including transport carrying case per unit / All specifications are subject to change without further notice |
---|