PORTABLE RESISTIVE 270 V DC LOAD BANK with DIGITAL POWER METER; WiFi & USB CONNECTION CAPABLE

Advantages

  • Simple operation suitable for non-trained operators and personnel; no maintenance required
  • Suitable for workshop or airside operation; silent unit rated at < 70 dB(A) at 7m / 23Ft
  • Cant protection – load bank works only when positioned on flat horizontal surface
  • Digital load banks do not require any further calibration process once delivered
  • Free DEKAL licensed software application and proper drivers included
  • All measurements possible to archive and printout, including diagram graphics
  • In accordance & fully complied with AFI 33-115 volume 2, Certified by: SAF/A6C
  • Housing made of non-corrosive parts with component quality control by the manufacturer
  • High reliability with multiple thermal protection – extremely resistant to high temperature
  • Extra safety and isolated jack sockets for connecting external voltage measuring device
  • Short worldwide delivery period with tracking feature and insurance for all products
  • Spare parts availability and accurate on-time deliveries by appointed courier
  • Transport casing with pull up handle as standard for every load bank manufactured
  • 2 years full warranty with extension option for all DEKAL load banks
  • CE certification – health, safety, and environmental protection standards
  • Made for GPU’s testing procedure according to ISO 6858, DFS 400, ARP 5015
  • Classification CE marking, DIN, VDE, IEC, IP 21 protection rate level
  • Customs classification Harmonized System tariff code HS: 8516808000

PORTABLE RESISTIVE 270 V DC LOAD BANK with DIGITAL POWER METER; WiFi & USB CONNECTION CAPABLE

TECHNICAL SPECIFICATION
MLB-72DW
VOLTAGE [V] * FREQUENCY [Hz]
270 V DC ± 5 %
LOAD / POWER [kW / kVA cosφ=1]
0 – 72 kW ± 5 %
3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5% FS+2C
V / A / kW
WiFi & USB INTERFACE SPECIFICATIONS
RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW]
28 V DC load (THREE STAGE SWITCH)
FORCED AIR COOLING [m³/min & CFM]
51.45 m³/min – 1817 CFM
SIZE, WEIGHT & CLASSIFICATION
TESTING PROCEDURE ACCORDING
ISO 6858, DSF 400, MIL-SPEC ARP, 5015
DEVICE CLASSIFICATION
CE marking, DIN, VDE, IEC
LOAD BANK SIZE [L x W x H] mm / Kg
630 x 225 x 445 / 25
LOAD BANK SIZE [L x W x H] In / Lbs
24.8 x 8.8 x 17.5 / 55
TRANSPORT CASING [L x W x H] mm / Kg
690 x 290 x 550 / 19
TRANSPORT CASING [L x W x H] In / Lbs
27.2 x 11.4 x 21.6 / 42
Including transport carrying case per unit / All specifications are subject to change without further notice
error: Content is protected !!