400Hz AC ANALOG PANEL LOAD BANK – ALBM-80AP
0 out of 5
Advantages
- Simple operation suitable for non-trained operators
- Silent operations < 70 dB(A) at the distance of 7m / 23Ft
- Suitable for workshop and/or airside operation
- Environmental operating temperature from -20 ºC to 55 ºC / -4 ºF to 122 ºF
- Transport casing with pull up handle as standard for each load bank
- Triple thermal protection – extremely resistant to high temperature
- Cant protection – load bank works only in horizontal position
- Phase detection – load bank works only if all ABC phases are available
- Phase rotation indicator – phase sequence of three-phase voltages
- Fine regulation as standard for all Digital and Analogue 400 Hz AC load banks
- Aluminum housing and non-corrosive parts
- High component quality control by manufacturer
- High reliability – effective standardization process
- Isolated jack sockets – unique user friendly safety feature for external voltage test
- Spare parts availability and accurate on-time deliveries
- Short worldwide delivery period with tracking feature & insurance
- 2 years full warranty with extension option for all DEKAL load banks
- CE certification – health, safety, and environmental protection standards
- Made for GPU’s testing procedure according to ISO 6858, DFS 400, ARP 5015
- Classification CE marking, DIN, VDE, IEC, IP 21 protection rate level
SKU: ALBM-80AP
Category: ANALOG PANEL - AP
400Hz AC ANALOG PANEL LOAD BANK – ALBM-80AP
- TECHNICAL SPECIFICATION
- INDICATIONS
- DIMENSIONS & WEIGHT
| TECHNICAL SPECIFICATION | ALBM-80AP |
|---|---|
| VOLTAGE [V] * FREQUENCY [Hz] | 115 / 200 V AC ± 10 % * 400 Hz ± 10 % |
| LOAD / POWER [kW / kVA cosφ=1] | 0 – 80 kW ± 5 % |
| FINE ADJUSTMENT – POTENTIOMETER | 0 – 8 kW |
| RATE SWITCH REG. LOAD STEPS ± 5% ROUGH ADJUSTMENTS – 8 kW STEPS POWER [kW / kVA cosφ=1] |
9 SEQUENCE STEPS: 8 – 16 kW 16 – 24 kW 24 – 32 kW 32 – 40 kW 40 – 48 kW 48 – 56 kW 56 – 64 kW 64 – 72 kW 72 – 80 kW |
| FORCED AIR COOLING [m³/min & CFM] | 66.15 m³/min – 2340 CFM |
| INDICATIONS | |
|---|---|
| ANALOG VOLT METER | VOLT METER – MOVING IRON CLASS 1.5 |
| ANALOG AMPERE METER | AMPERE METER – MOVING IRON CLASS 1.5 |
| ANALOG FREQUENCY METER | FREQUENCY METER – MOVING IRON CLASS 0.5 |
| LIGHT INDICATION | PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT |
| GPU TESTING PROCEDURE*
|
*Proposal procedure: LOAD raising from 0 → 100% ? 30 seconds; HOLD at 100% ? 5 minutes; LOAD decrease from 100 → 0% ? 10 minutes |
| ENGINE DECARBONISING*
|
*Proposal procedure: LOAD raising from 0 → 100% ? 30 seconds; HOLD at 100% ? 45 minutes; LOAD decrease from 100 → 0% ? 15 minutes |
| DIMENSIONS & WEIGHT | |
|---|---|
| LOAD BANK SIZE [L x W x H] mm / Kg | 600 x 230 x 630 / 27 |
| LOAD BANK SIZE [L x W x H] In / Lbs | 23.6 x 9.05 x 24.8 / 59 |
| TRANSPORT CASING [L x W x H] mm / Kg | 710 x 290 x 860 / 19 |
| TRANSPORT CASING [L x W x H] In / Lbs | 27.9 x 11.4 x 33.9 / 42 |
| LOAD BANK PAINTING / TRANSPORT CASING | POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM |