• 400 Hz Digital USB Load Banks DU

    Dekal Load Banks

    The shortest lead times in industry

400 HZ DIGITAL USB LOAD BANKS

Color variations

Advantages

  • Simple operation suitable for non-trained operators
  • Silent operations < 70 dB(A) at the distance of 7m / 23Ft
  • Suitable for workshop and/or airside operation
  • Environmental operating temperature from -20 ºC to 55 ºC / -4 ºF to 122 ºF
  • Transport casing with pull up handle as standard for each load bank
  • Triple thermal protection – extremely resistant to high temperature
  • Cant protection – load bank works only in horizontal position
  • Phase detection – load bank works only if all ABC phases are available
  • Phase rotation indicator – phase sequence of three-phase voltages
  • Fine regulation as standard for all Digital and Analogue 400 Hz AC load banks
  • Aluminum housing and non-corrosive parts
  • High component quality control by manufacturer
  • High reliability – effective standardization process
  • Isolated jack sockets – unique user friendly safety feature for external voltage test
  • Spare parts availability and accurate on-time deliveries
  • Short worldwide delivery period with tracking feature & insurance
  • 2 years full warranty with extension option for all DEKAL load banks
  • CE certification – health, safety, and environmental protection standards
  • Made for GPU’s testing procedure according to ISO 6858, DFS 400, ARP 5015
  • Classification CE marking, DIN, VDE, IEC, IP 21 protection rate level

400 Hz LOAD BANKS - DIGITAL USB

Select an available model:

TECHNICAL SPECIFICATION
ALBM-45DU
VOLTAGE [V] * FREQUENCY [Hz]
115 / 200 V AC ± 10 % * 400 Hz ± 10 %
LOAD / POWER [kW / kVA cosφ=1]
0 – 48 kW ± 5 %
FINE ADJUSTMENT – POTENTIOMETER
0 – 8 kW
RATE SWITCH REG. LOAD STEPS ± 5%
ROUGH ADJUSTMENTS – 8 kW STEPS
POWER [kW / kVA cosφ=1]
5 SEQUENCE STEPS:
8 – 16 kW
16 – 24 kW
24 – 32 kW
32 – 40 kW
40 – 48 kW
FORCED AIR COOLING [m³/min & CFM]
44.10 m³/min – 1560 CFM
MEASUREMENTS & INDICATIONS
DIGITAL POWER METER PARAMETERS
USB INTERFACE SPECIFICATIONS
3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003;
DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA;
USB PLUG IN CONNECTION FOR DATA PRINTOUT / ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE
LIGHT INDICATION
PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT
GPU TESTING PROCEDURE*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 5 minutes;
LOAD decrease from 100 -> 0% 10 minutes
ENGINE DECARBONISING*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 45 minutes;
LOAD decrease from 100 -> 0% 15 minutes
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
600 x 230 x 630 / 25
23.6 x 9.05 x 24.8 / 55
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
710 x 290 x 860 / 19
27.9 x 11.4 x 33.9 / 42
LOAD BANK PAINTING / TRANSPORT CASING
POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM
Including transport carrying case per unit / All specifications are subject to change without further notice
TECHNICAL SPECIFICATION
ALBM-80DU
VOLTAGE [V] * FREQUENCY [Hz]
115 / 200 V AC ± 10 % * 400 Hz ± 10 %
LOAD / POWER [kW / kVA cosφ=1]
0 – 80 kW ± 5 %
FINE ADJUSTMENT – POTENTIOMETER
0 – 8 kW
RATE SWITCH REG. LOAD STEPS ± 5%
ROUGH ADJUSTMENTS – 8 kW STEPS
POWER [kW / kVA cosφ=1]
9 SEQUENCE STEPS:
8 – 16 kW
16 – 24 kW
24 – 32 kW
32 – 40 kW
40 – 48 kW
48 – 56 kW
56 – 64 kW
64 – 72 kW
72 – 80 kW
FORCED AIR COOLING [m³/min & CFM]
66.15 m³/min – 2340 CFM
MEASUREMENTS & INDICATIONS
DIGITAL POWER METER PARAMETERS
USB INTERFACE SPECIFICATIONS
3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003;
DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA;
USB PLUG IN CONNECTION FOR DATA PRINTOUT / ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE
LIGHT INDICATION
PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT
GPU TESTING PROCEDURE*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 5 minutes;
LOAD decrease from 100 -> 0% 10 minutes
ENGINE DECARBONISING*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 45 minutes;
LOAD decrease from 100 -> 0% 15 minutes
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
600 x 230 x 630 / 27
23.6 x 9.05 x 24.8 / 59
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
710 x 290 x 860 / 19
27.9 x 11.4 x 33.9 / 42
LOAD BANK PAINTING / TRANSPORT CASING
POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM
Including transport carrying case per unit / All specifications are subject to change without further notice
TECHNICAL SPECIFICATION
ALBM-100DU
VOLTAGE [V] * FREQUENCY [Hz]
115 / 200 V AC ± 10 % * 400 Hz ± 10 %
LOAD / POWER [kW / kVA cosφ=1]
0 – 100 kW ± 5 %
FINE ADJUSTMENT – POTENTIOMETER
0 – 8 kW
RATE SWITCH REG. LOAD STEPS ± 5%
ROUGH ADJUSTMENTS – 8 kW STEPS
POWER [kW / kVA cosφ=1]
12 SEQUENCE STEPS:
8 – 16 kW
16 – 24 kW
24 – 32 kW
32 – 40 kW
40 – 48 kW
48 – 56 kW
56 – 64 kW
64 – 72 kW
72 – 80 kW
80 – 88 kW
88 – 96 kW
96 – 104 kW
FORCED AIR COOLING [m³/min & CFM]
88.20 m³/min – 3120 CFM
MEASUREMENTS & INDICATIONS
DIGITAL POWER METER PARAMETERS
USB INTERFACE SPECIFICATIONS
3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003;
DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA;
USB PLUG IN CONNECTION FOR DATA PRINTOUT / ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE
LIGHT INDICATION
PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT
GPU TESTING PROCEDURE*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 5 minutes;
LOAD decrease from 100 -> 0% 10 minutes
ENGINE DECARBONISING*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 45 minutes;
LOAD decrease from 100 -> 0% 15 minutes
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
600 x 230 x 630 / 30
23.6 x 9.05 x 24.8 / 66
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
710 x 290 x 860 / 19
27.9 x 11.4 x 33.9 / 42
LOAD BANK PAINTING / TRANSPORT CASING
POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM
Including transport carrying case per unit / All specifications are subject to change without further notice
TECHNICAL SPECIFICATION
ALBM-120DU
VOLTAGE [V] * FREQUENCY [Hz]
115 / 200 V AC ± 10 % * 400 Hz ± 10 %
LOAD / POWER [kW / kVA cosφ=1]
0 – 120 kW ± 5 %
FINE ADJUSTMENT – POTENTIOMETER
0 – 8 kW
RATE SWITCH REG. LOAD STEPS ± 5%
ROUGH ADJUSTMENTS – 8 kW STEPS
POWER [kW / kVA cosφ=1]
14 SEQUENCE STEPS:
8 – 16 kW
16 – 24 kW
24 – 32 kW
32 – 40 kW
40 – 48 kW
48 – 56 kW
56 – 64 kW
64 – 72 kW
72 – 80 kW
80 – 88 kW
88 – 96 kW
96 – 104 kW
104 – 112 kW
112 – 120 kW
FORCED AIR COOLING [m³/min & CFM]
88.20 m³/min – 3120 CFM
MEASUREMENTS & INDICATIONS
DIGITAL POWER METER PARAMETERS
USB INTERFACE SPECIFICATIONS
3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003;
DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA;
USB PLUG IN CONNECTION FOR DATA PRINTOUT / ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE
LIGHT INDICATION
PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT
GPU TESTING PROCEDURE*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 5 minutes;
LOAD decrease from 100 -> 0% 10 minutes
ENGINE DECARBONISING*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 45 minutes;
LOAD decrease from 100 -> 0% 15 minutes
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
600 x 230 x 630 / 33
23.6 x 9.05 x 24.8 / 73
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
710 x 290 x 860 / 19
27.9 x 11.4 x 33.9 / 42
LOAD BANK PAINTING / TRANSPORT CASING
POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM
Including transport carrying case per unit / All specifications are subject to change without further notice
TECHNICAL SPECIFICATION
ALBM-140DU
VOLTAGE [V] * FREQUENCY [Hz]
115 / 200 V AC ± 10 % * 400 Hz ± 10 %
LOAD / POWER [kW / kVA cosφ=1]
0 – 140 kW ± 5 %
FINE ADJUSTMENT – POTENTIOMETER
0 – 8 kW
RATE SWITCH REG. LOAD STEPS ± 5%
ROUGH ADJUSTMENTS – 8 kW STEPS
POWER [kW / kVA cosφ=1]
14 SEQUENCE STEPS:
8 – 16 kW
16 – 24 kW
24 – 32 kW
32 – 40 kW
40 – 48 kW
48 – 56 kW
56 – 64 kW
64 – 72 kW
72 – 80 kW
80 – 88 kW
88 – 96 kW
96 – 104 kW
104 – 112 kW
112 – 120 kW
120 – 128 kW
128 – 136 kW
136 – 144 kW
FORCED AIR COOLING [m³/min & CFM]
88.20 m³/min – 3120 CFM
MEASUREMENTS & INDICATIONS
DIGITAL POWER METER PARAMETERS
USB INTERFACE SPECIFICATIONS
3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003;
DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA;
USB PLUG IN CONNECTION FOR DATA PRINTOUT / ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE
LIGHT INDICATION
PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT
GPU TESTING PROCEDURE*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 5 minutes;
LOAD decrease from 100 -> 0% 10 minutes
ENGINE DECARBONISING*
*Proposal procedure:
LOAD raising from 0 -> 100% 30 seconds;
HOLD at 100% 45 minutes;
LOAD decrease from 100 -> 0% 15 minutes
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
600 x 230 x 630 / 35
23.6 x 9.05 x 24.8 / 77
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
710 x 290 x 860 / 19
27.9 x 11.4 x 33.9 / 42
LOAD BANK PAINTING / TRANSPORT CASING
POWDER COATING FINE STRUCTURE 71319 IGP – SWISS QUALITY / HIGH GRADE ALUMINUM
Including transport carrying case per unit / All specifications are subject to change without further notice

Color variations